Common LEV Compliance Mistakes Employers Make

vector image

Installing an LEV system is just the beginning of managing dust, fumes, and vapours in the workplace. For this system to function efficiently, proper care and maintenance are essential. When this is ignored, risks to workers' health are greatly increased.

Many errors can arise regarding LEV compliance. Small problems, such as examinations not taking place and poor maintenance and training, may significantly affect the system's efficiency. Awareness of these problems will help employers maintain proper workplace conditions and COSHH compliance.

Table of Contents

Why Is LEV Compliance Important?

The Local Exhaust Ventilation system is important for preventing contaminants from reaching employees' breathing zone. It is widely used in many industries, including manufacturing, construction, woodworking, engineering, pharmaceuticals, laboratories, and the food industry.

Where hazardous substances cannot be eliminated, employers are often required to implement suitable control measures. According to the HSE COSHH Guidance, employers must prevent or adequately control exposure to substances that can damage health. Employers are also expected to ensure control measures remain effective throughout their use, not simply at the point of installation.

An LEV system that is poorly maintained or incorrectly used may fail to provide the protection it was designed to deliver. This can increase exposure risks and potentially result in enforcement action, project delays, increased sickness absence, or costly corrective work.

Compliance is more than just following regulations. An effective LEV system will limit exposure, improve the work environment, and demonstrate that the business is serious about ensuring a safe workplace. For most businesses, the LEV system is one of the primary control measures for air contaminants.

What Are the Most Common LEV Compliance Mistakes?

1. Failing to Carry Out Regular LEV Testing

One of the most common LEV compliance mistakes is assuming that an extraction system will continue to perform effectively without formal examination.

According to HSE LEV Guidance, most LEV systems will need a thorough examination and test at least once every 14 months. This helps verify whether the LEV system is still controlling airborne contaminants as expected.

Failing to conduct any testing can lead to issues that may not be detected in time, including airflow restrictions, damaged ductwork, and clogged filters.

Businesses can avoid this issue by scheduling regular LEV Testing Services and ensuring examinations are carried out at appropriate intervals.

2. Neglecting Routine Maintenance

Some organisations focus on formal testing but overlook day-to-day maintenance.

However, even a well-designed LEV system may have operational problems if proper maintenance is not undertaken. The filters may get blocked, the ducting may get damaged, and the fans may become inefficient.

Maintenance problems include:

  • Filter clogs and damage
  • Leaks in ductwork
  • Hood damage
  • Worn-out fan parts
  • Loose connections

These maintenance problems can be identified through regular inspections and preventative maintenance.

Businesses seeking ongoing support may benefit from Maintenance & Contracts to help keep systems operating efficiently between examinations.

3. Assuming One LEV System Suits Every Process

Not all extraction systems are designed to control the same contaminants. A system that performs well in one environment may be unsuitable in another.

For example, extraction requirements for welding fumes differ significantly from those needed for controlling wood dust or pharmaceutical powders. Factors such as contaminant type, particle size, airflow requirements, and work processes all influence system design. Assuming that one solution will suit every application is a common LEV compliance mistake that can leave workers inadequately protected.

This is why many businesses seek professional LEV Design Services when installing new systems or reviewing existing arrangements.

4. Poor Positioning of Extraction Hoods

Even a correctly designed LEV system can perform poorly if extraction hoods are positioned incorrectly.

The closer a hood is to the source of contamination, the more effective it is likely to be. If workers move extraction arms away from the process or fail to position them correctly, contaminants may escape into the workplace atmosphere before they can be captured.

This issue is particularly common in:

  • Welding operations
  • Grinding activities
  • Laboratory work
  • Manual production processes

Regular supervision and employee training can help minimise this problem.

5. Inadequate Employee Training

Another common LEV compliance mistake is assuming employees automatically understand how to use extraction systems correctly.

Workers should understand:

  • Why LEV systems are used
  • How the equipment operates
  • Proper positioning of extraction equipment
  • Symptoms that might suggest a problem
  • When to raise an alarm

In the absence of proper training, a good system can fail to offer sufficient protection.

6. Failing to Keep Accurate Records

LEV compliance is not only about system performance. Documentation also plays an important role.

Employers should maintain records of:

  • Thorough Examination and Tests
  • Maintenance activities
  • Repairs
  • System modifications
  • Employee training

Good records help demonstrate compliance and are useful during any system review process. During inspections, poor record-keeping can cause problems even when the equipment is performing well.

7. Ignoring Changes to Workplace Processes

Workplaces rarely remain unchanged.

New machinery, modified production processes, increased workloads, or changes to materials can all affect extraction requirements. A system that was suitable several years ago may no longer provide adequate protection if workplace activities have changed significantly.

For instance, a fabrication shop might use an LEV system for controlling welding fumes. After several years, the organisation will undertake additional tasks, such as grinding and cutting. Even though the original LEV system would work fine, it would not necessarily provide sufficient control for the other tasks the organisation introduced over time.

8. Failing to Act on LEV Test Findings

A Thorough Examination and Test is only valuable if employers act on the findings.

Some organisations receive reports highlighting deficiencies but delay corrective action due to operational pressures or budget concerns.

Common findings may include:

  • Reduced airflow
  • Damaged ductwork
  • Worn filters
  • Poor hood positioning
  • Inadequate system performance

Ignoring these issues can allow problems to worsen and increase worker exposure risks. Prompt corrective action helps maintain system effectiveness and supports ongoing compliance.

9. Not Reviewing LEV Logbooks and Documentation

Many employers keep compliance records because they know they are required to do so, but fewer use those records as a practical management tool.

LEV logbooks contain valuable information about maintenance activities, test results, repairs, and system performance. Reviewing these records regularly can help identify recurring issues before they become more serious.

Common documentation issues include:

  • Maintenance records not kept
  • Examination reports not completed
  • System changes not recorded
  • Old inspection data
  • Corrective action records missing

Good documentation supports compliance and helps businesses demonstrate that control measures are being actively managed.

Why Do These Mistakes Happen?

Many LEV compliance mistakes occur because businesses view compliance as a one-time exercise rather than an ongoing process.

Common reasons include:

  • Lack of awareness
  • Budget constraints
  • Competing operational priorities
  • Inadequate training
  • Poor maintenance planning
  • Failure to review workplace changes

In some cases, employers assume that because an LEV system was installed correctly, it will continue to perform effectively without further attention. In reality, effective LEV compliance management requires ongoing monitoring, maintenance, testing, and review.

How Can Businesses Improve LEV Compliance?

Improving compliance does not necessarily require major changes. Often, a structured approach can significantly reduce risk and improve long-term performance.

Good practices include:

  • Scheduling regular LEV inspections
  • Carrying out regular maintenance
  • Training staff on proper system usage
  • Checking changes in the workplace regularly
  • Keeping good records
  • Dealing with defects quickly
  • Seeking expert advice where necessary

The guidance contained within HSG258: Controlling Airborne Contaminants at Work provides practical information on the design, operation, maintenance, and testing of LEV systems. It remains one of the most widely recognised resources for organisations managing workplace exposure risks.

What Role Does Regular Testing Play?

Regular testing is one of the most important elements of effective LEV compliance management.

Testing helps verify that:

  • Airflow remains adequate
  • Filters are functioning correctly
  • Components are operating properly
  • Capture effectiveness remains suitable
  • The system continues to control contaminants effectively

Without testing, employers may have no reliable way of knowing whether their extraction systems are providing the protection workers require.

Professional LEV Consultancy can also help organisations review existing arrangements and identify opportunities for improvement where necessary.

How Can DevineAir Help?

Managing LEV compliance can be challenging, particularly for organisations operating multiple sites or complex processes. Working with experienced specialists can help businesses identify risks, maintain effective controls, and avoid many of the common mistakes discussed in this article.

DevineAir provides companies throughout the UK with LEV Testing Services, LEV Consultancy, LEV Design Services, and Maintenance & Contracts. No matter what your needs may be, whether it is a Thorough Examination and Test, support for improving the system or assistance with compliance issues, we are here to help.

If you are unsure whether your existing LEV system complies with the regulations, DevineAir can help. Contact DevineAir today and see how we can help you with your LEV systems.

FAQs

What are the most common LEV compliance mistakes?

Common errors in LEV compliance include a lack of thorough examinations and tests, inadequate maintenance, insufficient documentation, insufficient training, and failure to evaluate systems when work processes change.

How often should LEV systems be tested?

Most LEV systems require a Thorough Examination and Test at least every 14 months, although some systems may require more frequent examination depending on the application and associated risks.

Why is employee training important for LEV compliance?

The staff members should be aware of the proper use of the extraction system and the symptoms of improper functioning.

What records should employers keep for LEV compliance?

Businesses should maintain records of examinations, maintenance activities, repairs, employee training, and any modifications made to the system.

Can a compliant LEV system become non-compliant over time?

Yes. Changes to workplace processes, damaged components, missed maintenance, or overdue examinations can all affect system performance and compliance if not properly managed.

Related Posts

November 11, 2026
LEV Testing Certificates and Compliance Records

After an LEV system has been thoroughly examined and tested, businesses may refer to the resulting paperwork as an LEV testing certificate. However, a certificate or test label should not be confused with the full compliance record. The important document is the Thorough Examination and Test (TExT) report, which records what was examined, how the […]

Read More
November 3, 2026
Choosing an LEV Testing Provider in the UK

A Thorough Examination and Test (TExT) requires a competent person who can examine the system, assess its performance and identify issues that could affect the control of airborne contaminants. When choosing an LEV testing company in the UK, compare competence, relevant experience, testing scope and reporting quality rather than price alone.  This guide explains what […]

Read More
menu