A Thorough Examination and Test (TExT) requires a competent person who can examine the system, assess its performance and identify issues that could affect the control of airborne contaminants. When choosing an LEV testing company in the UK, compare competence, relevant experience, testing scope and reporting quality rather than price alone.
This guide explains what to look for and what to ask before appointing an LEV testing provider.
Table of Contents:
Quick Answer: What Should You Look for in an LEV Testing Company?
A suitable LEV testing provider should be able to demonstrate the knowledge, skills and practical experience needed to examine your particular system.
When comparing providers, consider:
- the competence of the person carrying out the examination;
- relevant LEV qualifications and training;
- experience with similar LEV systems and processes;
- what is included in the Thorough Examination and Test;
- how system performance will be assessed;
- what information the examiner needs from you;
- the quality of the final report; and
- how defects and recommended actions will be communicated.
HSE's guidance on LEV competence emphasises that the level of knowledge and capability required should reflect the complexity of the work and the consequences if the control system fails.
Why Competence Matters When Choosing an LEV Testing Provider
A Thorough Examination and Test is intended to establish whether an LEV system can continue to perform as intended and contribute to adequate control of exposure.
That requires more than operating test instruments.
The examiner needs to understand how LEV works, how the system is intended to control the contaminant and how to interpret measurements and observations in the context of the process.
HSE's HSG258 guidance on controlling airborne contaminants at work describes competence as having sufficient training, knowledge and experience to carry out the work properly.
The more complex the LEV system or the greater the potential consequences of inadequate control, the greater the level of competence likely to be required.
When choosing a provider, therefore, ask about the competence of the person who will actually carry out the examination rather than relying solely on general claims made by the company.
What Qualifications Should an LEV Tester Have?
There is no single qualification that every LEV examiner must hold.
HSG258 identifies relevant professional qualifications and training routes through organisations including the British Occupational Hygiene Society (BOHS), CIBSE and ILEVE.
Qualifications can therefore provide useful evidence of relevant technical training, but they should be considered alongside practical experience.
HSE's guidance is clear that competence is based on the appropriate combination of knowledge, skills and experience.
When comparing providers, useful questions include:
- What LEV qualifications does the examiner hold?
- How much practical testing experience do they have?
- What types of systems have they examined?
- Do they have experience relevant to your industry or process?
- How do they maintain their technical knowledge?
Look for Experience Relevant to Your LEV System
LEV systems are not all alike. Before appointing an LEV testing company in the UK, ask whether the examiner has experience with:
- your industry;
- the contaminant being controlled;
- similar hood arrangements;
- your type of extraction system;
- comparable processes; and
- systems of similar complexity.
A provider does not necessarily need to have tested an identical installation before. However, the examiner should have sufficient relevant experience to understand the system and recognise when further investigation is needed.
Check What Is Included in the LEV Test
Not every quotation necessarily includes the same scope.
Before comparing prices, establish exactly what each provider proposes to do.
HSG258 describes TExT as a detailed and systematic examination sufficient to establish whether the LEV can continue to perform as intended and contribute to adequate control of exposure.
Depending on the system, an examination may involve:
- visual and structural examination;
- function checks on relevant components;
- technical performance measurements;
- comparison with appropriate performance information;
- assessment of control effectiveness; and
- identification of defects and remedial actions.
When requesting quotations from different providers, make sure you are comparing equivalent scopes rather than assuming every “LEV test” includes the same work.
Ask How Performance Will Be Assessed
Taking measurements is only part of an LEV examination.
The examiner also needs appropriate information against which current performance can be assessed.
Ideally, this will include the original commissioning information or another suitable performance benchmark.
Useful records can include:
- the commissioning report;
- previous TExT reports;
- user manuals;
- design information;
- system drawings;
- airflow or pressure benchmarks;
- maintenance records; and
- details of modifications.
HSE guidance explains that LEV testing should consider the system against the standards established during commissioning.
A provider that asks for existing documentation before the examination can use it to understand what the system is intended to do and whether its performance has changed.
If commissioning information is missing, ask the provider how this will be addressed rather than assuming that a benchmark can simply be estimated.
What Should an LEV Testing Report Include?
The report is one of the most important outputs of a Thorough Examination and Test.
It should provide enough information for the employer to understand what was examined, how the system performed and what action is required.
HSG258 states that the examination and testing report should contain a prioritised list of remedial actions for the employer.
Depending on the system and findings, a useful report should clearly record relevant information such as:
- system identification;
- examination findings;
- technical measurements;
- performance comparisons;
- defects;
- observations;
- remedial actions; and
- conclusions about system performance.
The employer's engineer and the person responsible for health and safety should be able to use the report to understand what needs attention.
Be cautious about treating a test sticker or simple pass/fail certificate as the entire outcome of the examination. The written report is an important part of managing the LEV after the test.
Ask to See an Example LEV Report
If you are comparing providers, consider asking for an anonymised example report. This can show whether findings, measurements, defects and recommended actions are presented clearly enough to be useful in practice.
Technical detail matters, but an employer should not have to interpret pages of measurements without being told what the findings mean for the LEV system.
Find Out How Defects Will Be Reported
Before appointing a provider, ask how underperforming systems, significant defects and remedial actions will be communicated. HSG258 states that the examination report should include a prioritised list of remedial actions, so findings should be presented clearly enough for the employer to understand what requires attention.
A useful provider should also be able to explain technical findings without turning every issue into a generic recommendation for additional services.
Consider Objectivity as Well as Technical Ability
HSG258 states that a Thorough Examination and Test should be carried out by someone who is competent and able to make an objective assessment of the LEV.
That person can be an external contractor or a competent employee of the LEV owner.
Using an external testing company is therefore not automatically a legal requirement.
However, whoever conducts the examination should be able to assess the system objectively and identify deficiencies where they exist.
When using a commercial provider, it is reasonable to ask how findings and recommendations are determined, particularly where the same company may also offer maintenance or remedial services.
Recommendations should follow from the condition and performance of the LEV rather than simply creating additional work.
Compare LEV Testing Quotes Carefully
Price is a legitimate consideration, but the lowest quotation may not provide the best comparison if the scope differs.
When obtaining quotes, check:
- how many LEV systems are included;
- how many hoods or extraction points will be examined;
- what measurements will be taken;
- what documentation is required;
- what the final report includes;
- whether defects and remedial actions will be clearly documented;
- whether test labels are included;
- whether travel or other charges apply; and
- whether clarification of the report is available afterwards.
What Information Should You Give the LEV Testing Company?
The quality of an examination can depend partly on the information available to the examiner. Before the visit, provide relevant commissioning information, previous TExT reports, maintenance records and details of any repairs or changes to the process, machinery or LEV configuration.
A well-maintained LEV logbook may also provide useful information about routine checks, faults and maintenance between formal examinations.
Tell the provider about any significant changes since the previous test, as these may affect whether existing performance benchmarks remain appropriate.
Understand Which UK Requirements Apply
If you operate sites in different parts of the UK, it is worth checking that the provider understands the applicable regulatory framework.
Great Britain and Northern Ireland do not operate under the same COSHH regulations.
In England, Scotland and Wales, the relevant requirements are set out in the Control of Substances Hazardous to Health Regulations 2002.
Northern Ireland operates under the Control of Substances Hazardous to Health Regulations (Northern Ireland) 2003.
For Northern Ireland, HSENI's COSHH guidance states that most LEV equipment must be thoroughly examined and tested by a competent person at least every 14 months. Schedule 4 specifies exceptions for certain processes, and more frequent TExT may be appropriate where system effectiveness could deteriorate between examinations.
The corresponding HSE guidance for Great Britain also identifies statutory Thorough Examination and Testing and relevant exceptions.
A provider working nationally should therefore be able to identify which regulatory requirements apply to the site being examined.
Questions to Ask an LEV Testing Company Before Hiring Them
Before accepting a quotation, consider asking the following questions.
1. Who will actually carry out the LEV test?
2. What LEV qualifications and practical experience does the examiner have?
3. Have you tested systems similar to ours?
4. What exactly does the quotation include?
5. What records do you need before testing?
6. What will be included in the final report?
7. How will defects or underperformance be reported?
Clear answers to these questions can make it easier to compare providers on competence and scope rather than price alone.
Potential Warning Signs When Comparing Providers
No single factor automatically means that an LEV testing company is unsuitable. However, further questions may be worthwhile if a provider:
- cannot tell you who will carry out the examination;
- provides little evidence of relevant LEV competence;
- does not ask about the system or process;
- cannot clearly explain what the quotation includes;
- treats TExT as simply taking a few airflow readings;
- does not ask whether commissioning or previous test information exists;
- cannot explain what the report will contain; or
- makes broad promises about compliance before examining the system.
A professional-looking certificate should not be the main basis for choosing a provider.
The quality of the examination and the usefulness of the resulting information matter more.
Frequently Asked Questions
How often does LEV need testing?
LEV used to control exposure to hazardous substances will generally require Thorough Examination and Testing at least every 14 months under the relevant COSHH requirements, although shorter maximum intervals apply to certain processes. More frequent testing may also be appropriate where system effectiveness could deteriorate between examinations.
Employers should check the requirements that apply to their particular process and UK jurisdiction.
Is LEV testing a legal requirement?
Where LEV is provided as an engineering control under COSHH, it is subject to statutory Thorough Examination and Testing requirements. The applicable examination interval depends on the equipment and process.
In Great Britain, the relevant requirements are set out under COSHH 2002. Northern Ireland has separate requirements under COSHH (Northern Ireland) 2003.
Who can carry out LEV testing?
LEV Thorough Examination and Testing should be carried out by a competent person with sufficient knowledge, skills and practical experience for the work involved.
The examiner needs to understand LEV performance, use appropriate testing methods, interpret the results and make an objective assessment of whether the system can continue to perform as intended and contribute to adequate control of exposure.
Does an LEV tester need a P601 qualification?
HSE does not specify P601 as a universal legal requirement for carrying out LEV Thorough Examination and Testing.
A relevant qualification such as P601 can provide evidence of technical training, but qualification alone does not establish competence. The examiner should also have appropriate knowledge, practical skills and experience relevant to the systems being examined.
How much does LEV testing cost?
There is no single standard price for LEV testing. The cost will depend on factors such as the number and complexity of systems, the number of hoods or extraction points, the testing required, site conditions and the scope of reporting.
When comparing quotations from LEV testing companies, check exactly what is included rather than comparing the total price alone. A provider should be able to clarify the proposed testing scope before work is arranged.
Choosing the Right LEV Testing Provider
Choosing an LEV testing company in the UK should involve more than comparing price or checking whether a certificate will be issued. Consider the examiner's competence and relevant experience, the proposed testing scope and whether the final report will provide clear, useful findings and remedial actions.
DevineAir provides LEV Thorough Examination and Testing for organisations across the UK and Ireland. Our team includes consultants with P601, P602, P603 and P604 qualifications, and our testing service includes visual and structural examination, technical performance measurements, assessment of control effectiveness and HSG258-based reporting.
If you are arranging LEV testing or comparing providers, contact DevineAir to discuss your systems and the appropriate testing scope for your site.
This article provides general information about choosing an LEV testing provider. The appropriate examination and testing requirements depend on the workplace, process, LEV system and applicable jurisdiction.